The bootloader element lacks the mapping for grub-pc and extlinux
This adds it.
Change-Id: Ic7b82903f02faaab143d2bd682876bf4853fd90d
Closes-Bug: 1534387
While the patch looks sane and the change worked locally,
it has broke the ironic-inspector gate. As we're close
to deprecating the DIB ramdisk in favor of IPA, I suggest
reverting it.
This reverts commit 802f14862c.
Change-Id: I0525e545cb2fe8ce184312a2f9bbe3763904f61a
Closes-Bug: #1534648
Our bootloader install fails on non-gentoo builds due to missing pkg-map
for grub-pc. This map should really live in the bootloader element, so
move it there and fill it out.
Change-Id: Ib11b9df84b593ab25232729a570c812f1b4b8774
uses upstream's stage4 images, includes all the needed bells and
whistles for openstack on kvm.
Change-Id: Ibca43173c30c2a74a73a2e2d9dd6d6d832c62694
Closes-Bug: 1530911
This patch is fixing a syntax error in the 70-ironic-root-device init
script for the deploy-ironic element.
Change-Id: I767486ca5893605720fba41bee3af72725a26377
Closes-Bug: #1531835
This element allows installation of pip and virtualenv from either
distro packages or git.
Change-Id: Id294f0936c8fef8a3b27a415bfcc93b3f327e104
Depends-On: I731cc8a0f5bfeda8f17a78c33b9f44062323a361
Use dib-python to run package-installs using the provided python
version. Automatically detect the python version for our
package-installs-squash since that runs outside the chroot.
Change-Id: I926022bcf8cbcd81b051026ffd5d6477650045ad
Fedora has changed the location of epel, shorting the link
from 'download.fedoraproject.org' to 'dl.fedoraproject.org'.
This change updates the epel mirror to prevent it from timing
out.
Change-Id: I87090282a2f5f757495daec6ad14123b436b1aa0
Due to a bug in how we were running some of our phases we were not
detecting some nonzero exit's. When this is fixed, dib fails early during
cleanup (leaving some resources attatched) due to not propertly
accounting for pipefail.
Change-Id: Icc0b35acbe035cac12a9291e2d07b6c690c3a6ad
This fix uses dmidecode and awk to simply multiply by 1024 when
the value is represented in GB, otherwise it returns the given
value. I should note that I've only observered this occurence
on "some" SuperMicro Hardware
Closes-Bug: #1486689
Change-Id: I352b1891326f72af3a56c7bbe8b7f3c422169404
Install selinux policy packages as part of the base-installs. selinux
is part of the base-system and the kernel boots by default in selinux
mode.
Without both of these, we can get in a situation where later scripts
(particuarly, some of the infra scripts) might install systemd-policy
without a base policy (targeted), leading to a messed up situation
where systemd will halt during boot due to missing policy files.
Change-Id: I6bf156304d1134fb328fba9b12dc364701b13696
Add an environment variable to control the creation of eth0/1
interface enablement scripts.
With a tool such as glean, the presence of these scripts will indicate
the interface is configured and configuration-drive settings will not
be applied. This means in a non-dhcp situation like on Rackspace,
network is broken.
On Fedora, where later systemd provides "predictable network interface
names" [1] eth0 & eth1 ironically aren't predictable so this just
confuses things. You really need cloud-init or glean or something to
bring up your interfaces in a sane fashion.
This maintains the status-quo on centos-minimal, but disables creation
for fedora-minimal.
[1] http://www.freedesktop.org/wiki/Software/systemd/PredictableNetworkInterfaceNames/
Change-Id: I3f1ffeb6de3b1f952292a144efab9554f7f99a5f
As described in the comment, systemd will create a broken
/etc/resolv.conf link if there is no file in the base-image (as you
can read in the bug, it is debated if this is a bug or a feature).
The solution is to leave a dummy /etc/resolv.conf file in the image.
Whatever network manager you choose (NetworkManager, glean,
cloud-config, etc) will overwrite this anyway.
It's just that some tools, such as dhclient, get confused with the
broken symlink. This affects you if you're using glean to configure
the network in a DHCP situation, for example -- dhclient won't
configure nameservers and everything goes to heck.
Change-Id: I734834d03e7fdb13f9ab2e86f877b07bf4a84ff9
We are incorrectly detecting major/minor device numbers for the growroot
rootfs. This can also be simplified by querying udev for partition
information.
Change-Id: I68059bf11f2563872f6b4d0e23fa09a15de980a8
The detection logic in pkg-map for DIB_DEBUG_TRACE assumes that this
variable being unset means tracing is on, when in fact this means
tracing is off.
Change-Id: I584a634c57bbe03e26a6ee94cef473e634616885
With a slow file system, umount can return 0 and the immediately
following remove can fail with a "Device or resource busy" error.
This happened in DevStack in disk-image-create where unmount_image
is followed by an immediate cleanup_build_dir.
Solution is to apply same logic from bug 1332521 to allow the
remove to retry on failure (up to 5s) in case the umount has not
completed.
Change-Id: I3337e2b4ad0111e77f79dc179439cdfea8ebdeda
Closes-Bug: #1527721
We perform a check for this file after an image build fails to see if it
was intentional. This outputs a message which looks like the failure is
a result of the check when the file is missing which is very confusing
to users. Lets be more quiet about it.
Change-Id: I9b1f6c7c57021d11b4f91cd3c33846fae692b928
End user docs would benefit from a section about the byte-to-inode
ratio, and why it's set the way it is. This update explains why
and how to manipulate the ratio depending on the intended use.
Change-Id: Iffb5ef6f4c7c74f4aa6e25912d4991d7a611c8fe
Closes-bug: 1512841
In order to add more flexibility to the vm and bootloader
elements, split the functionality in two different ones, and
make vm depend on bootloader element.
This will allow to construct more elements that depend on
bootloader, and develop both elements independently.
Change-Id: Iad2503b7b8fe53b768a3bc79e4cb839700fbd747
This element enables creation of Ubuntu deploy ramdisk and
user images which could be used to deploy the HP Proliant
Servers with Dynamic Smart Array Controllers. Without this driver
the disk with the Dynamic Smart Array Controller is
not visible to the ramdisk.
Closes bug: #1492803
Change-Id: Ibb3b298cd379cd7333279484df6ae30e9d7f6aaa