epel-release 7.2 has been superseded by 7.5, so update accordingly.
this time, detect the available epel-release package from the repo
instead of hardcoding version number which will break build each
time the version number gets bumped up.
Change-Id: I29c73355a85112840b57f93b39a9eeda421875e6
We don't export DIB_RELEASE in the base distro scripts, so many
times it will be an unset variable in 51-bootloader from the vm
element. Currently that script doesn't handle the situation
properly and we get errors like:
line 160: [: =: unary operator expected
This change quotes the references to DIB_RELEASE so that won't
happen anymore.
Change-Id: Ic8f91804334f8862c217f465be80e96d3116f5c8
We have a good pattern of namespacing env vars with DIB_. Add support
for DIB_PYPI_MIRROR_URL* and maintain backwards compat support.
Change-Id: I434c9d1b14cd571b20754c9ad7cd64c936f8399a
It is an established convention to use DIB_IMAGE_CACHE in elements to
refer to the cache location. This convention has not been documented
in the README, unlike other element development practices. This change
adds documentation for DIB_IMAGE_CACHE both from an element user and
developer perspective.
This change was prompted by I76030654e7dfc7b7d4dfa87e082c14e7cee479b9
Change-Id: I6fcc2409450cdb45e5afcb292908fbaee1af258a
As we started using jq it makes sento to use it everywhere when
building a resulting JSON.
Also removes some unneeded code.
Change-Id: Ib1391dc9f4e1463a9a3d0c13909ff60e3c993e82
When setting IPMI credentials is requested, ironic-discoverd
will return ipmi_setup_credentials=true, ipmi_username and ipmi_password
in response. Use ipmitool to set credentials in this case.
Change-Id: I8ace9e817e5ce9dbfb8564feec4a3ce6c0e1b233
This is much easier to remember than the full commandline - and keeps
this project in line with others
Change-Id: I2f631c25d8839272941b7c8d4bb571a853422083
Both ccache and linux-image-generic were being installed by
install-packages rather than using a package-installs.yaml.
Change-Id: Ib54c5b51d605278bb9d046a897be989c17c6fb0f
Patch adds support to create PowerPC image with vm element.
It creates 2 partitions, one for PReP boot and other for root and
installs grub-ieee1275.
Change-Id: I4675ef2b82aa69b63e63a1cc7db01b0c0e6f9fff
Closes-Bug: 1418739
Since the package-installs-squash script relies on the defined
environment variables for figuring out what the values are for an
element's install type and the default install types, sudo -E must be
used to preserve the environment.
Change-Id: Ice5cf0bca65d8078f84daedbef123fc73d5a7b63
Working on host systems without selinux, where the guest image
does have selinux, creates a situation where the instance will
have about a 1 minute delay on first boot because it must relabel.
The previous check for sysfs assumes that the host system has
selinux, which is not needed for the guest setfiles to work.
Change-Id: Ic186a45991b6d80880ad635e9c80985612f53a05
Closes-bug: 1414200
This patch extends the deploy-ironic element to make it install a
bootloader on the disk in case the boot_option parameter passed in the
kernel command line is set to "local".
This parameter is set by Ironic as part of the
blueprint local-boot-support-with-partition-images
Change-Id: I5ebe6f364ae0ac408939399e5f28728b41c4766e
Deprecated the `--expand-dependencies` flag from `element-info` usage.
The flag was required and not optional. We can rely on argparse to exit non-0
when the required positional argument is not provided.
Change-Id: Iaf8eb962eb600760974bc33c30b809a07a23278e
Closes-Bug: 1265649
When building the ramdisk we don't cleanup the temporary
directories after ourselves. This leaves /tmp/image.* directories
mounted and /tmp/image.* directories on the system.
Also the ramdisk-functions duplicate, from what I can see,
the cleanup function from common-functions. So when a job
is killed off it ends up leaving /tmp/image.* directories
on the system.
Change-Id: I2d73aabd0eb176027b4e7368580db08902e2b6ab
Patch adds support for PowerPC Big-endian and Little-endian local
fedora VM images and using VM images with two partitions, PReP
boot and root partition. Since PowerPC requires PReP boot
partition to be present.
Change-Id: Iba03226e187609df898732c13b1aa5f895b156e3
Closes-Bug: 1413487
ramdisk-image-create assumes the presence of vmlinuz file in OS image.
But ubuntu PPC LE images have only vmlinux file. This patch adds
support for using vmlinux file.
Change-Id: I5dd0b8ceb46b73be57d4c15b39b96f99b524fa3f
Closes-Bug: 1413362
When set to true this cloud-init setting overwrites the /etc/hosts
file at reboot, breaking stuff in TripleO where controllers rely
on resolving each other by name. We still want cloud-init to add in
there a mapping for the local fqdn, so we switched to 'localhost' [1]
1. http://bazaar.launchpad.net/~cloud-init-dev/cloud-init/trunk/view/head:/doc/examples/cloud-config.txt#L470
Change-Id: I85468dece3b67f39841aa826f9b7ca4bf113027a
Closes-Bug: 1411594
This commit adds http_proxy=$http_proxy to use apt-get update through a
http-proxy.
Change-Id: Iee589f6d11b84991512493d22f0e3dbfe60736ec
Closes-Bug: #1412314
The rhel-common element has a script that uses subscription-manager
to register an instance of RHEL with the customer portal or Satellite.
If os-refresh-config runs this script more than once,
subscription-manager returns a non-zero value causing os-refresh-config
to fail. Adding --force to the subscription-manager calls doesn't
properly unregister the image from Satellite and the result is multiple
content host registrations. This patch changes the registration to only
run once.
Change-Id: If372e7f59bbdc77e2b233024c1342f005004f2e5